Vertical oil fired boiler
Oil-fired boiler is a product of KS PTI manufactured to apply in industrial fields requiring heat such as laundry, wood drying, cooking, food processing... completely environmentally friendly. Especially, Indochina oil-fired boilers have been installed at: garment factories, fabric dyeing factories, printing factories, animal feed processing factories, confectionery factories, beverage factories, etc. factory fish sauce, soy sauce and vegetable oil…
Features and characteristics
Materials for manufacturing high-grade oil-fired boilers.
The design of the high-grade oil-fired boiler avoids overheating.
Oil fired boilers with corrugated furnace tubes have the effect of increasing the heat transfer area and avoiding the phenomenon of expansion.
Low water protection, over temperature protection, over pressure protection.
A good oil fired boiler is a boiler that is automatically welded with a high pressure and heat resistant welding rod.
The new oil fired boiler ensures maintaining steam supply with correct pressure and flow.
Start-up is quick and quiet, fully automatic and very easy to use.
Guarantee
DETAIL | TIME |
Electrical control system | 01 year |
Engine | 02 years |
Case body | 05 years |
Features and characteristics
Materials for manufacturing high-grade oil-fired boilers.
The design of the high-grade oil-fired boiler avoids overheating.
Oil fired boilers with corrugated furnace tubes have the effect of increasing the heat transfer area and avoiding the phenomenon of expansion.
Low water protection, over temperature protection, over pressure protection.
A good oil fired boiler is a boiler that is automatically welded with a high pressure and heat resistant welding rod.
The new oil fired boiler ensures maintaining steam supply with correct pressure and flow.
Start-up is quick and quiet, fully automatic and very easy to use.
Guarantee
DETAIL | TIME |
Electrical control system | 01 year |
Engine | 02 years |
Case body | 05 years |
Introduce
Boiler model KS – MW water tube type, standing. Used to produce fast saturated steam because of the small amount of water, the fuel combines with the air and burns inside the combustion chamber to create a high-temperature combustion product (smoke), after moving out of the furnace pipe is pass 1. , smoke continues to move outside the pipe through the wing wall through pass 2 and pass 3 to transfer heat to the water to generate steam to supply the whole system, the smoke reduces the temperature and then enters the chimney to discharge combustion products to the environment. In addition, the KS-MW boiler has a compact installation area and a very large lifespan compared to coal, biomas and biomass fuel furnaces, etc. Pressure is from 10-15 bar, efficiency high>90%, the maximum capacity of 3 tons/h is chosen by many factories.

Structure

Furnace body
Steam ball, water ballon use heat-resistant steel A515 – Gr.70, A516 – Gr.70 according to American standards.
Water pipes use cast steel pipes according to ASTM A106 Gr.B according to European standards. Arranged in groups to increase heat exchange efficiency.
The top cap of the 2 ballons has a manhole for easy cleaning and maintenance during use.
The boiler body is covered with Rockwool insulation with a density of 120kg/m3, and the outside is covered with 304 stainless steel.
Main equipment included
Water heater: Take advantage of the heat of high-temperature flue gas to heat the feed water before supplying it to the boiler to increase steam generation speed, save fuel, and improve boiler efficiency.
Electrical control cabinet : PLC, HMI and SCADA control devices (on request) have the function of receiving fault of boiler control devices. In addition, it also warns the boiler operator that it is time for routine maintenance. The electrical equipment in the electrical cabinet uses Europe and Japan.
Water pump cluster : Including two pumps from G7 countries, the pump is run alternately to avoid overcapacity or damage. Large capacity furnaces are equipped with an inverter to control the pump to avoid power consumption and reduce pump life.
Water treatment system : The boiler system is equipped with a water softening system, which improves steam quality, reduces blowdown time and deposits inside the boiler, and increases boiler life. In addition, the company’s large capacity furnaces are equipped with a degassing tank, to remove oxygen insoluble in water before supplying it to the boiler.
Burner : In the KS-HB boiler, burners of Oil/Gas are used from: Weishaut, Riello, Olympia of Germany, Italy and Japan. The noise of the boiler is less than 85dB, 2m from the furnace house. This type of furnace has a horizontal burner to increase equipment life.
Exhaust smoke treatment system: KS-HB furnace system is installed with an exhaust smoke treatment system to achieve exhaust gas quality according to QCVN 19:2009/BTNMT standard of the Ministry of Natural Resources and Environment.
The accessories included: Including valves and pressure gauges, switches and controllers originating from G7

Application & Quality
Application
Horizontal industrial boiler is widely used for different industries: textile factory, food and beverage factory, chemical factory, paper factory, plastic factory, garment factory, crystal oil processing, shoe making factory, printing factory, school, hotel, swimming pool, laundry, pharmaceutical, medical, greenhouse, farm, etc….
Quality
Calculation & design: According to ASME, EC, AS standards.
Manufacturing process: According to TCVN (TCVN 7704 – 2007; TCVN 6413 – 1998; TCVN 8366 – 2010)
Input materials with full CO and CQ certificates are tested before use. Welds are welded by automatic welding machine, non-destructive testing, ultrasonic and magnetic testing, penetration testing. Fully pressure tested, test pressure is equal to 1.5 times design pressure.
Hydrostatic test will be carried out for strength test and boiler body sealing test. The test pressure is 1.5 times the design pressure. The testing process is under the direction of experts of the pressure equipment testing center. Test results serve as the basis for issuing inspection dossiers for boilers.

Specifications
Model | ĐVT | KS-MW100 | KS-MW150 | KS-MW200 | KS-MW250 | KS-MW300 | KS-MW350 | KS-MW400 | KS-MW500 | KS-MW750 | KS-MW1000 | KS-MW1500 | KS-MW2000 | KS-MW2500 | KS-MW3000 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Công suất | kg/h | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 500 | 750 | 1000 | 1500 | 2000 | 2500 | 3000 |
Áp suất thiết kế | kgf/cm2 | 8 | 8 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Tiêu hao nhiên liệu | Kg/h | 7 | 10 | 13 | 17 | 21 | 25 | 30 | 35 | 53 | 70 | 105 | 140 | 175 | 210 |
Số Pass khói | Pass | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Điện nguồn | V | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 |
Độ dày thân | mm | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 12 | 12 | 12 | 12 | 14 | 14 | 14 |
Bảo ôn | mm | 70 | 70 | 70 | 75 | 75 | 75 | 75 | 75 | 100 | 100 | 100 | 100 | 100 | 100 |
Hiệu suất | % | 86 | 86 | 86 | 86 | 86 | 86 | 86 | 86 | 86 | 86 | 86 | 86 | 86 | 86 |
Bơm cấp nước | lít/h | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 |
Bồn nước cấp | Lít | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 500 | 750 | 1000 | 1500 | 2000 | 2500 | 3000 |
Bồn dầu | Lít | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 500 | 750 | 1000 | 1500 | 2000 | 2500 | 3000 |
Kính thủy | - | 21x1 | 21x1 | 21x1 | 21x2 | 21x2 | 21x2 | 21x2 | 21x2 | 21x2 | 21x2 | 21x2 | 21x2 | 21x2 | 21x2 |
Van hơi chính | - | 34 | 34 | 34 | 42 | 42 | 42 | 42 | 49 | 60 | 60 | 76 | 90 | 90 | 114 |
Van cấp nước | - | 27 | 27 | 27 | 27 | 27 | 34 | 34 | 34 | 34 | 34 | 42 | 42 | 42 | 42 |
Van một chiều | - | 27 | 27 | 27 | 27 | 27 | 34 | 34 | 34 | 34 | 34 | 42 | 42 | 42 | 42 |
Van an toàn | - | 27x1 | 27x1 | 34x1 | 34x1 | 34x1 | 34x1 | 42x1 | 42x1 | 34x2 | 34x2 | 42x2 | 42x2 | 49x2 | 49x2 |
Van xả đáy | - | 27 | 27 | 34 | 34 | 34 | 34 | 34 | 34 | 34 | 42 | 42 | 42 | 42 | 42 |
Van xả khí | - | 21 | 21 | 21 | 21 | 21 | 21 | 21 | 21 | 21 | 21 | 21 | 21 | 21 | 21 |
Đường kính ống khói | 100 | 120 | 140 | 168 | 180 | 220 | 240 | 265 | 285 | 320 | 340 | 360 | 400 | 420 | |
L | mm | 900 | 1000 | 1050 | 1120 | 1200 | 1300 | 1350 | 1480 | 1580 | 1580 | 1660 | 2000 | 2600 | 2900 |
W | mm | 800 | 850 | 1000 | 1100 | 1150 | 1200 | 1230 | 1270 | 1300 | 1300 | 1450 | 1890 | 2100 | 2300 |
H | mm | 1330 | 1750 | 1900 | 2100 | 2100 | 2150 | 2200 | 2230 | 2270 | 2400 | 2610 | 2850 | 3300 | 3500 |